Specs Top Image
Building Specifications
  • Owner: William Kaufman Organization
  • Property Manager: Sage Realty Corporation
  • Original Developer: William Kaufman Organization
  • Architect: FXFowle
  • Building Area: 296,000 RSF
  • Number of Floors: 40+ cellar
  • Construction: Steel reinforced concrete with brick façade
  • Floor-to-Floor Heights: (2-6) 11'11"; (7-39) 10'10"; (40) 11'11"
  • Finished Ceiling Heights: 8'4" throughout
  • Floor Loads: 50lbs psf live load for tenant floors
  • Electrical: 5 watts per usf demand load exclusive of base building air conditioning; 460 volt, 3 phase main service
  • Elevators: Armor elevator; 6 Passenger elevators: 1-17 (3); 18-39 (3); Freight elevator: Serves all floors except 40th floor
  • HVAC: Roof mounted 850-ton cooling tower, individual water-cooled package units on each floor, controlled by BMS system in engineers office. Individual area control is provided by therma-fuser self contained diffusers. Heat is distributed through perimeter hot water heating.
  • Life Safety: Class "E" Fire Command Station located in freight lobby; Building is partially sprinklered and is being retrofitted as space becomes available to comply with NYC building code.
  • Supplemental Cooling: Available (no charge for condenser water usage)
  • Extended Hours of Operation: Standard hours of operation are Mon - Fri 8am-6pm; Overtime HVAC is provided at tenant’s request and the tenant pays only electric charges.
  • Building Management: System: BMS system utilizes direct digital control technology for monitoring and control of building systems.
  • Security: 24/7 Uniformed security in lobby. DVR system for surveillance and swipe card system for lobby entrance.
  • Telecom: High Speed Connectivity & Telecom Providers
  • Accessibility: The building is partially ADA compliant.
  • Tenant Access: 24/7 access with building ID
  • Windows Dimensions: Three sizes throughout - 82" X 21"; 66" X 52.5"; 66" X 21"
  • Column Spacing: (2-6) Fifteen interior columns; (7-40) Four interior columns
  • Perimeter Columns: (7- 40) Positioned along mullions to minimize interrupted vision